Andrés Meana-Fernández

Thermal Machines and Engines Area



Contact

Andrés Meana-Fernández

Thermal Machines and Engine Area


Curriculum vitae


andresmf[at]uniovi[dot]es


Department of Energy

University of Oviedo




Andrés Meana-Fernández

Thermal Machines and Engines Area


andresmf[at]uniovi[dot]es


Department of Energy

University of Oviedo



Thermal response and failure mode evaluation of a dry-type transformer


Journal article


Pelayo E. Blanco Alonso, A. Meana-Fernández, J. M. Fernández Oro
Applied Thermal Engineering, vol. 120, 2017, pp. 763-711


Cite

Cite

APA   Click to copy
Alonso, P. E. B., Meana-Fernández, A., & Oro, J. M. F. (2017). Thermal response and failure mode evaluation of a dry-type transformer. Applied Thermal Engineering, 120, 763–711. https://doi.org/10.1016/j.applthermaleng.2017.04.007


Chicago/Turabian   Click to copy
Alonso, Pelayo E. Blanco, A. Meana-Fernández, and J. M. Fernández Oro. “Thermal Response and Failure Mode Evaluation of a Dry-Type Transformer.” Applied Thermal Engineering 120 (2017): 763–711.


MLA   Click to copy
Alonso, Pelayo E. Blanco, et al. “Thermal Response and Failure Mode Evaluation of a Dry-Type Transformer.” Applied Thermal Engineering, vol. 120, 2017, pp. 763–11, doi:10.1016/j.applthermaleng.2017.04.007.


BibTeX   Click to copy

@article{pelayo2017a,
  title = {Thermal response and failure mode evaluation of a dry-type transformer},
  year = {2017},
  journal = {Applied Thermal Engineering},
  pages = {763-711},
  volume = {120},
  doi = {10.1016/j.applthermaleng.2017.04.007},
  author = {Alonso, Pelayo E. Blanco and Meana-Fernández, A. and Oro, J. M. Fernández}
}

Abstract

In this work, the safe working limits of a 10 kVA dry-type transformer with H-class insulation are determined by modeling its thermal response in different scenarios using numerical simulations (CFD). A numerical model of the heat transfer from the transformer to its surroundings by natural convection has been developed. Firstly, a steady regime with the transformer working at full load at an ambient temperature of 300 K is studied in order to gain insight into the heat transmission mechanisms. Then, a series of 32 steady simulations with different load and ambient conditions is performed to characterize insulation aging due to overheating. Finally, a second group of 9 transient simulations is employed to assess the transformer failure time under an overload situation. The results show a coupling between the thermal and flow fields. The hot spot temperatures obtained by the model are consistent with previous experimental observations and the time that the transformer resists an overload has been calculated. The results obtained allow the prediction of the thermal behavior of a transformer under different scenarios, reducing the need for instrumentation, as well as experimental tests which result in the loss of the testing transformer.

Keywords

Numerical analysis; Electrothermal effects; Power transformer losses; Power transformer insulation; Failure analysis